fortress interlocks

 

Common assemblies


Login

 
  Not a registered visitor? Click here.
Personal information


 

ATSTOP

ATSTOP
ATSTOP024
24V AC/DC
ATSTOP048
48V AC/DC
ATSTOP110
110V AC
ATSTOP230
230V AC
ATSTOPASI
AS-Interface
+ATSTOP
Tongue operated safety gate switch

The ATSTOP has a heavy duty tongue and head where the tongue allows a  +/- 12mm misalignment. The tongue and head unit can rotate in 90° increments. The product is ideally designed for machines without run down cycles where quick and frequent access to equipment is required, via either hinged or sliding doors.

When the machinery is in operation the tongue is engaged and the power is on. If accesss is required, the door is simply opened releasing the tongue from the unit,giving positively guided, forced disconnection of the safety switch contacts.






Safety Data

Standards 2006/95/EC (Low voltage directive), 2006/42/EC (The machinery directive), 2004/108/EC (The EMC Directive), EN60947-5-1:2004, EN61010-1:2001, EN1088:1996, EN12100-1:2003, EN12100-2:2003, EN13849-1: 2006, EN62061:2006, EN61000-6-2:2005, EN61000-6-3:2007
Certifications CE marked for all applicable directives
Category Cat. 4, PLe (EN/ISO 13849-1) and SIL3 (EN/IEC 62061)
Functional safety data* B10d 11.656.340
MTTfd High > 385 years (72852,1 years)
CCF 90%
DC High 99% (with correct monitoring of both channels and including the opposite-mode monitoring switch)
PFHd [1/h] 1,57E-09

* use the "Functional Safety Calculator" to calculate values with varying conditions
** amGard modules need to be constructed as a complete assembly to reach stated values